Choose a repeatable bottle datum and observe the label without manual repositioning during the approved production passes. “Operator-free” here means that no operator corrects the bottle or label by hand between those passes. The trial can be supervised normally and the machine stays in its authorised state.
Record the angle and the arrival condition
| Observation | What to record | Purpose |
|---|---|---|
| First reference pass | Use the same two points on the label and the same reference plane. | Keeps the direction of skew comparable. |
| Second pass under identical conditions | Signed height difference and bottle orientation at entry. | Shows whether the same deviation recurs. |
| Result example | 2.1 mm difference across 60 mm on the measurement plane. | arctan(2.1 ÷ 60) is about 2.0° in this example. |
Preserve the sign and position of the deviation
Agree which direction is positive. On a curved package use the approved fixture or packaging test method. Keep the roll, SKU, position and speed stable for the repeat runs. A change in incoming orientation calls for a different check from a repeat deviation with identical entry.
Attach the fixture drawing, measured values and the first or repeat position to a labeller enquiry. State the acceptance criterion from the actual pack specification.
Use the labeller format-parts register to capture the matching setup
Share the label skew trial with the reference fixture, recorded angles and the repeat condition.